30 5710 pdf standard concrete pad without sidewalk for 15kv 25kv s c vista 422 auto transformer switchgear.
Electrical transformer pad design.
The 75 kva style iie transformer will fit on the largest style iie pad.
The 300 kva style iie transformer will fit on the small style iie pad.
From small stabilizing pads to large transformer foundations oldcaslte infrastructure equipment pads are durable and convenient foundations for your equipment needs.
To request blue stake call 811 or 1 800 stake it 800 782 5348.
The applicant must frame the concrete transformer pad or purchase a pre cast pad before called tep for an inspection.
30 5512 pdf standard concrete pad for 25 kv pmh 3 switch enclosure.
Download this 3d autocad model of a power transformer for use in your electrical design 3d cad drawings.
Design drawings pertaining to a vault installation shall be uniformly prepared and sealed by the customer s design professional.
To request a power kill or access to tep equipment call 520 918 8300.
Pad mount transformers operate on medium voltage distribution systems up to about 35 kv.
Standard concrete pad with sidewalk for 15 kv pme 9 auto transformer switchgear.
Calls must be made at least five working days in advance.
Manufacturer s proposed specifications for the electrical service equipment.
The 2 500 kva style iie transformer will sit on the old 80 x 106 pad but the radiators will overhang the pad.
Wood float finish leaving no depressions.
Transformer pads all dimension in inches a 104 reinforcing bars 13 4 98 secondary c 3 4.
Schneider electric usa website.
2 8 1 transformer test schedule 2 8 2 design tests 2 8 3 routine and other tests part 3 execution 3 1 installation 3 2 grounding 3 2 1 grounding electrodes 3 2 2 pad mounted transformer grounding 3 2 3 connections 3 2 4 grounding and bonding equipment 3 3 installation of equipment and assemblies 3 3 1 meters and current transformers.
6 the style iie transformers will fit on style iib iic llf pads.
Electrical symbols transformers generators transformer symbol.
30 5053 pdf standard concrete pad without for 15 kv pme 9 auto transformer switchgear.
Some utility companies such as pacific gas electric which serves my area of california already have ready made transformer pad designs for a large number of transformer sizes as well as pad designs for master meter assemblies etc.
Often being constructed in less than a day these pads are readily available for immediate installation without waiting for curing like pour in place alternatives.
Reinforcing steel atsm a615 grade 60 place approximately 6 from each other and securely tied together.
Download cad block in dwg.
You might want to check with your local utility.
The low voltage winding matches the customer requirement and may be single phase or three phase.
Architectural drawings and specifications relating to the electric service equipment and transformer pad location.